• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
GROUP II TERMINAL DISASSEMBLY
GROUP II TERMINAL ASSEMBLY

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  1029    1030    1031    1032    1033  1034  1035    1036    1037    1038    1039  
img
.
TM 5-3895-379-23-1
0195
GROUP II TERMINAL DISASSEMBLY - Continued
1
2
M1005SWR
Figure 12.
Wiring Repair.
WARNING
Tip of removal tool is very sharp. Use caution when using tool. Failure to comply may cause
injury to personnel.
3.
Insert removal tool (Figure 13, Item 2) into cavity (Figure 13, Item 3) on connector (Figure 13, Item 1) until
seated.
4.
Pull wire (Figure 13, Item 6) back through connector (Figure 13, Item 1) and remove tool.
NOTE
Perform Step (5) only if old terminal is still attached to wire.
Make cut directly behind damaged terminal.
5.
Cut terminal (Figure 13, Item 4) and wire seal (Figure 13, Item 5) from wire (Figure 13, Item 6). Discard terminal
and seal.
2
1
3
6
4
5
M1006SWR
Wiring Repair.
Figure 13.
0195-13
03/15/2011Rel(1.8)root(maintwp)wpno(M00133)


Privacy Statement