TM 5-3895-379-23-1
0195
FEMALE CABLE CONNECTOR REPLACEMENT
1.
Slide outer shell (Figure 6, Item 2) and sleeve (Figure 6, Item 1) back on wire (Figure 6, Item 3).
2.
Remove contact (Figure 6, Item 5) from wire (Figure 6, Item 3).
3.
Trim end of wire (Figure 6, Item 3) as needed to make an undamaged end.
NOTE
If trimming causes wire to become too short, refer to WIRE SPLICING USING BUTT
CONNECTORS or WIRE SPLICING USING SOLDER METHOD in this work package.
4.
Remove 1/4 in. (6.4 mm) of insulation (Figure 6, Item 4) from end of wire (Figure 6, Item 3).
5.
Install sleeve (Figure 6, Item 1) over end of wire (Figure 6, Item 3).
6.
Install contact (Figure 6, Item 5) securely into place.
7.
Crimp contact (Figure 6, Item 5) securely into place.
8.
Slide outer shell (Figure 6, Item 2) over sleeve (Figure 6, Item 1) and contact (Figure 6, Item 5).
9.
Be sure no bare wire (Figure 6, Item 3) shows outside of outer shell (Figure 6, Item 2).
1
2
4
5
3
M0999SWR
Figure 6. Female Cable Connector Replacement.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00133)