TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
a. If fuse filament is broken,
23. No Power to Accessories With Engine
2. Turn
fuse
holder
cap
notify
supervisor
for
Running - Continued.
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled KEY START. Inspect
fuse for broken filament.
b. If fuse filament is not broken,
fault is not corrected. Install
fuse and cap in fuse holder and
notify supervisor.
BROKEN FUSE
FILAMENT
401-085
HYDRAULIC SYSTEM
24. Hydraulic Oil Temperature is High
1. Check hydraulic oil level (WP
a. If hydraulic oil level is low, fill
(Warning Light and Warning Horn On).
b. If hydraulic oil level is not low,
fault is not corrected. Notify
supervisor.
HYDRAULIC OIL
COOLER
ACCESS
PLATE
401-087
RADIATOR
401-087