TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
PROPEL SYSTEM - CONTINUED
30. Roller Will Not Move When Propel Control
3. Check hydraulic oil level (WP
a. If hydraulic oil level is low, fill
Lever is Operated - Continued.
b. If hydraulic oil level is not low,
go to Step 4.
a. If fuse filament is broken,
4. Turn
fuse
holder
cap
notify
supervisor
for
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled BRAKE. Inspect fuse
for broken filament.
b. If fuse filament is not broken,
fault not corrected. Install fuse
and cap in fuse holder and
notify supervisor.
BROKEN FUSE
FILAMENT
401-085
31. Propel System Engages Very Slowly When
Check hydraulic oil level (WP
a. If hydraulic oil level is low, fill
Making a Shift.
b. If hydraulic oil level is not low,
fault not corrected. Notify
supervisor.
a. If fuse filament is broken,
32. Propel System Does Not Change Speeds
Turn
fuse
holder
cap
notify
supervisor
for
When Propel Speed Switch Is Moved.
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled BRAKE. Inspect fuse for
broken filament.
b. If fuse filament is not broken,
fault not corrected. Install fuse
and cap in fuse holder and
notify supervisor.