TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
If roller still has no electrical
13. Starter Does Not Turn or Turns Slowly.
1. Open left-side door assembly
power, close left-side door
Step 2.
button.
a. If either fuse filament is
2. Turn fuse holder caps
broken, notify supervisor for
counterclockwise and remove
replacement. Install fuses and
caps and fuses from fuse
caps in fuse holders.
holders labeled KEY START
and BRAKE. Inspect fuses for
broken filament.
b. If fuse filaments are not
broken, fault is not corrected.
Install fuses and caps in fuse
holders and notify supervisor.
ALTERNATOR
BUTTON
401-091
BROKEN FUSE
FILAMENT
If roller still has no electrical
14. Starter Turns But Does Not Crank Engine.
1. Open left-side door assembly
power, fault is not corrected.
Close left-side door assembly
button.
BROKEN FUSE
FILAMENT
401-085