TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
VIBRATORY SYSTEM - CONTINUED
35. Vibratory System Will Not Forward and
b. If fuse filament is not broken,
Reverse Travel - Continued.
fault is not corrected. Install
fuse and cap in fuse holder and
notify supervisor.
BROKEN FUSE
CB534B ONLY
FILAMENT
401-085
36. Vibration Occurs in Only One Drum.
Place drum select switch is in
If fault is not corrected, notify
center (both drums) position.
supervisor.
WATER SPRAY SYSTEM
a. If water level is low, add water
1. Check water level gauges for
37. Spray Does Not Occur On Either Drum
water in water tanks. Indicator
When Water Spray Switch is in Continuous
needle pointing full left
Spray Position.
indicates tank is empty.
b. If water level is not low, go to
Step 2.
a. If water tank shutoff valves are
2. On CB534B, check that the
not open, open valves.
water tank shutoff valve at
b. If water tank shutoff valves are
each tank is open. Valve
open, go to Step 3.
handle will be in line with
valve when valve is open.