TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ELECTRICAL SYSTEM - CONTINUED
a. If fuse filament is broken,
21. Fuel Gauge Does Not Operate.
Turn
fuse
holder
cap
notify
supervisor
for
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled GAUGES. Inspect fuse
for broken filament.
b. If fuse filament is not broken,
fault is not corrected. Install
fuse and cap in fuse holder and
notify supervisor.
a. If fuse filament is broken,
22. Vibrations Per Minute (VPM) Gauge Does
Turn
fuse
holder
cap
notify
supervisor
for
Not Operate.
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled GAUGES. Inspect fuse
for broken filament.
b. If fuse filament is not broken,
fault is not corrected. Install
fuse and cap in fuse holder and
notify supervisor.
If roller still has no electrical
23. No Power to Accessories With Engine
1. Open left-side door assembly
power, fault is not corrected.
Running.
Close left-side door assembly
button.
BUTTON
401-093