TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
VIBRATORY SYSTEM
NOTE
33. Vibration Frequency Start-up is Slow, Time
Lag After Travel Starts is Excessive.
When systems are cold, cold bearing friction can cause slow
vibration frequency start-up and excessive lag time after
travel starts.
1. Ensure that systems are warm.
Stop roller, and allow systems to
warm up before attempting
mission. If symptom persists, go
to Step 2.
a. If vibratory bearing reservoir
2. Check vibratory bearing
is low of oil, fill vibratory
reservoir for correct level of oil
b. If vibratory bearing reservoir
oil is at correct level and soil
condition and base are correct,
fault is not corrected. Notify
supervisor.
a. If vibratory bearing reservoir
34. Vibration Mechanism is Noisy.
Check
vibratory
bearing
oil is low, fill vibratory bearing
reservoir for correct level of oil
b. If vibratory bearing reservoir
oil is at correct level, fault is
not
corrected.
Notify
supervisor.
35. Vibratory System Will Not Work Forward
1. Check hydraulic oil level (WP
a. If hydraulic oil level is low, fill
and Reverse Travel.
b. If hydraulic oil level is not low,
fault is not corrected. Notify
supervisor.
a. If fuse filament is broken,
2. Turn
fuse
holder
cap
notify
supervisor
for
counterclockwise and remove
replacement. Install fuse and
cap and fuse from fuse holder
cap in fuse holder.
labeled VIBE. Inspect fuse for
broken filament.