TM 5-3895-379-10
VIBRATORY BEARING RESERVOIR CHECK AND SERVICE
THIS WORK PACKAGE COVERS
Check, Fill
INITIAL SETUP
References
Tools and Special Tools
Checks and Services (PMCS) Introduction
Materials/Parts
Equipment Condition
Container, 1 qt. capacity
NOTE
The roller vibratory system consists of two similar vibratory systems located at each end of roller. The
vibratory bearing reservoir oil level gauges are located on left side of front drum and right side of rear
drum.
This work package covers checking and servicing of one vibrating bearing reservoir. Both vibratory
bearing reservoirs are checked and serviced in the same way.
CHECK
1.
2.
Move roller until bar (1) is at bottom of drum (2).
3.
4.
5.
Check oil level gauge (3). Oil level should fill half of viewing area of oil level gauge.
6.
Fill vibratory bearing reservoir when required. Refer to Fill in this work package.
3
2
1
401-106