• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
SEPARATE AND CONNECT VIBRATORY AND PROPEL PUMPS
Figure 2. Vibratory and Propel Pumps Separate

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  1112    1113    1114    1115    1116  1117  1118    1119    1120    1121    1122  
img
.
TM 5-3895-379-23-1
0202
SEPARATE
WARNING
Oil is very slippery. Immediately wipe up any spills. Failure to follow this warning may cause
injury.
CAUTION
Be sure work area is clean when working with hydraulic components. Contaminants entering
the system may damage components.
NOTE
Place vibratory and propel pump assemblies on wooden blocks for ease of access.
1.
Disconnect two hose assemblies (Figure 1, Item 1) from vibratory control valve (Figure 1, Item 4).
2.
Remove six bolts (Figure 1, Item 3) from vibratory control valve (Figure 1, Item 4) and vibratory pump
(Figure 1, Item 2).
3.
Remove vibratory control valve (Figure 1, Item 4) and spacer (Figure 1, Item 5) from vibratory pump
(Figure 1, Item 2).
4.
Remove four O-rings (Figure 2, Item 3) from spacer (Figure 1, Item 5) and vibratory control valve
(Figure 1, Item 4). Discard O-rings.
1
5
2
4
3
2
1
M0351SWR
Figure 1.
Vibratory and Propel Pumps Separate.
5.
Remove two bolts (Figure 2, Item 2) and separate vibratory pump (Figure 1, Item 2) from propel pump
(Figure 2, Item 1).
0202-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00140)