TM 5-3895-379-23-1
0202
SEPARATE
WARNING
Oil is very slippery. Immediately wipe up any spills. Failure to follow this warning may cause
injury.
CAUTION
Be sure work area is clean when working with hydraulic components. Contaminants entering
the system may damage components.
NOTE
Place vibratory and propel pump assemblies on wooden blocks for ease of access.
1.
Disconnect two hose assemblies (Figure 1, Item 1) from vibratory control valve (Figure 1, Item 4).
2.
Remove six bolts (Figure 1, Item 3) from vibratory control valve (Figure 1, Item 4) and vibratory pump
(Figure 1, Item 2).
3.
Remove vibratory control valve (Figure 1, Item 4) and spacer (Figure 1, Item 5) from vibratory pump
(Figure 1, Item 2).
4.
Remove four O-rings (Figure 2, Item 3) from spacer (Figure 1, Item 5) and vibratory control valve
(Figure 1, Item 4). Discard O-rings.
1
5
2
4
3
2
1
M0351SWR
Figure 1.
Vibratory and Propel Pumps Separate.
5.
Remove two bolts (Figure 2, Item 2) and separate vibratory pump (Figure 1, Item 2) from propel pump
(Figure 2, Item 1).
03/15/2011Rel(1.8)root(maintwp)wpno(M00140)