• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 2. Vibratory and Propel Pumps Separate
VIBRATORY AND PROPEL PUMPS REPLACEMENT

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  1114    1115    1116    1117    1118  1119  1120    1121    1122    1123    1124  
img
. .
TM 5-3895-379-23-1
0202
CONNECT - Continued
3.
Install vibratory control valve (Figure 4, Item 4) and spacer (Figure 4, Item 5) on vibratory pump
(Figure 4, Item 2).
4.
Install six bolts (Figure 4, Item 3) on vibratory control valve (Figure 4, Item 4) and vibratory pump
(Figure 4, Item 2).
5.
Connect two hose assemblies (Figure 4, Item 1) to vibratory control valve (Figure 4, Item 4).
1
5
2
4
3
2
1
M1225SWR
Figure 4. Vibratory and Propel Pumps Connect.
END OF TASK
FOLLOW-ON MAINTENANCE
Install vibratory and propel pumps. (WP 0203)
END OF TASK
END OF WORK PACKAGE
0202-4
03/15/2011Rel(1.8)root(maintwp)wpno(M00140)