TM 5-3895-379-23-1
0104
REMOVAL - Continued
3.
Remove nut (Figure 2, Item 1), screw (Figure 2, Item 6), and bracket (Figure 2, Item 4) from retaining clip
(Figure 2, Item 2) and mounting plate (Figure 2, Item 5).
4.
Remove nut (Figure 2, Item 1), screw (Figure 2, Item 7), retaining clip (Figure 2, Item 2), and mounting plate
(Figure 2, Item 5) from strainer and suction tube assembly (Figure 2, Item 3).
1
2
3
5
7
6
4
M0127SWR
Figure 2. Oil Strainer and Suction Tube Removal.
END OF TASK
CLEANING
WARNING
Cleaning compound, solvent MIL-PRF-680 Type III is an environmentally compliant and low
toxic material. However, it may be irritating to the eyes and skin. The use of protective gloves
and goggles is suggested. Use in well-ventilated areas. Keep away from open flames and
other sources of ignition.
1.
Clean strainer and suction tube assembly with cleaning compound, solvent.
2.
Dry strainer and suction tube assembly and ensure that all cleaning compound is removed prior to installation.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00043)