TM 5-3895-379-10
TROUBLESHOOTING PROCEDURES - CONTINUED
0010 00
Table 1. Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WATER SPRAY SYSTEM - CONTINUED
a. If water tank shutoff valve is
41. Water Consumption is Unequal Between
1. On CB534B, check that the
not open, open valve.
Tanks.
water tank shutoff valve at the
b. If water tank shutoff valve is
non-operating tank is open.
open, go to Step 2.
Valve handle will be in line
with the valve when the valve
is open.
WATER TANK
SHUTOFF VALVE
WATER
LEVEL GAUGE
CLOSED
OPEN
FRONT SIDE SHOWN
REAR SIDE SIMILAR
PLATE SHOWN
REMOVED FOR
401-094
CLARITY
2. Check for pinched or damaged
a. If a water line(s) is damaged,
water lines.
component is faulty, notify
supervisor.
b. If water lines are not damaged,
fault is not corrected. Notify
supervisor.
3. Check and service water spray
If malfunction continues, fault is
is
not
corrected.
Notify
supervisor.
42. Nozzle Spray Pattern is Inconsistent.
Check and service water spray
If malfunction continues, fault is
not corrected. Notify supervisor.
END OF WORK PACKAGE