RIM INSTALLATION.
POWER OPERATION.

Maintenance Manual For Roller, Pneumatic Tired Variable Pressure, Self-Propelled (Cce) Page Navigation
  91    92    93    94    95  96  97    98    99    100    101  
img
. .
SECTION 8
FINAL DRIVE AND TRANSFER CASE
To correct, move gear away from pinion. Then
move pinion toward gear to again obtain
correct backlash.
d. Figure 8-48 shows heavy contact on flank
or lower portion of tooth. To correct, move
pinion away from gear until contact to full
w o r k i n g depth of tooth without breaking
contact at flank. Then move gear toward pinion
to secure correct backlash.
e. Figure 8-49 shows heavy contact on face
of upper portion of tooth. To correct, move
pinion toward gear until contact covers flank of
tooth without breaking contact at face. Then
move gear away from pinion to secure correct
backlash.
FIGURE 8-45.
FIGURE 8-46.
FIGURE 8-48.
FIGURE 8-47.
FIGURE 8-49