TM 5-3895-379-23
HYDRAULIC OIL SAMPLING VALVE REPLACEMENT - CONTINUED
0141 00
REMOVAL
1.
Remove hydraulic oil sampling valve drain cap (1)
from hydraulic oil sampling valve (2).
NOTE
Use container to catch any hydraulic oil
that may drain from system. Dispose of oil
IAW local policy and ordinances. Ensure
all spills are cleaned up.
2.
Place container with 1 qt (0.9 l) minimum capacity
under hydraulic oil sampling valve (2).
3.
Turn and hold knurled knob (3) in direction of arrow
and allow remainder of hydraulic oil to drain.
4.
Loosen locking nut (4) on hydraulic oil sampling
valve (2) and remove hydraulic oil sampling valve
from tee (5).
5.
Remove O-ring (6) from hydraulic oil sampling valve
(2). Discard O-ring.
5
6
4
3
2
1
401-737
6.
If damaged, remove tee (5) from hydraulic oil pump
(7).
7.
Remove cap (8), preformed packing (9), boss reducer
7
(10) and two O-rings (11) from tee (5).
11
8
9
5
11
10
401-738
0141 00-2