TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2.
Starter Does Not Turn or Turns Slowly
- Continued.
STARTER RELAY
WIRE 306-GN
WIRE 200-BK
OUTPUT TERMINAL
WIRE
109-OR
WIRE 304-WH
INPUT TERMINAL
401-197
9. Check power to neutral start relay 1. If 24 to 28 Vdc are not measured
no. 1. Remove nine screws and
at terminal 4 (wire 307-OR), go to
washers. Remove panel assembly
Step 11.
from operator station. Remove
harness connector from neutral 2. If 24 to 28 Vdc are not measured
at terminal 3 (wire 330-YL) and
start relay no. 1. Turn and hold
BRAKE fuse is good, go to step
engine start switch to start (full
10.
right) position. Touch positive (+)
probe of multimeter to terminal 4 3. If 24 to 28 Vdc are measured at
(wire 307-OR) and negative (-)
terminals 3 and 4, turn engine start
probe of multimeter to good
switch to OFF position (TM 5-
ground. Measure voltage. Ensure
3895-379-10).
propel control lever is in neutral
position (TM 5-3895-379-10).
Move positive (+) probe of
330-YL) and measure. Turn
engine start switch to OFF
position (TM 5-3895-379-10).
0006 00-58