TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Starter Continues to Run After Engine 2.
Check for defective starter
relay 1. If
voltage does drop to
zero Vdc,
4.
switch assembly. Turn battery
Start Switch Key Is Released -
disconnect switch to OFF
Continued.
position (TM 5-3895-379-10). 2. If voltage does not drop to zero
Vdc, replace starter relay switch
Remove nut, washer and wire
304-WH (to starter) from starter
relay switch assembly. Turn
battery disconnect switch to ON
position (TM 5-3895-379-10).
Touch positive (+) probe of
306-GN) of starter relay switch
assembly. Touch negative (-)
ground. Have assistant turn
engine start switch to start
position
until
voltage
is
measurable on multimeter. Have
assistant turn engine start switch
to OFF position (TM 5-3895-
379-10). Voltage should drop to
zero Vdc.
STARTER RELAY
WIRE 306-GN
WIRE 200-BK
OUTPUT TERMINAL
WIRE
109-OR
WIRE 304-WH
INPUT TERMINAL
401-197
0006 00-63