TM 5-3895-379-23-1
0206
INSTALLATION
1.
Install propel control valve and lever assembly (Figure 5, Items 4 and 5), as a unit, to plate assembly
(Figure 5, Item 6).
2.
Install four bolts (Figure 5, Item 2) and nuts (Figure 5, Item 3) to plate assembly (Figure 5, Item 6).
3.
Install two wires (Figure 5, Item 7) to back-up alarm switch (Figure 5, Item 9).
4.
Connect electrical connector (Figure 5, Item 8).
5.
Install four hose assemblies (Figure 5, Item 10) to propel control valve (Figure 5, Item 5) and lever assembly
(Figure 5, Item 4).
6.
7.
Tighten hydraulic oil tank fill cap (Figure 5, Item 1).
1
2, 3
4
5
6
10
9
8
7
M0374SWR
Figure 5. Propel Control Lever Installation.
03/15/2011Rel(1.8)root(maintwp)wpno(M00144)