Figure 1. Propel Control Lever Removal
PROPEL CONTROL LEVER ASSEMBLY MAINTENANCE - Continued

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  1133    1134    1135    1136    1137  1138  1139    1140    1141    1142    1143  
img
.
TM 5-3895-379-23-1
0206
REMOVAL - Continued
3.
Loosen hydraulic oil tank fill cap (Figure 2, Item 1) to release hydraulic pressure.
NOTE
Tag and mark all lines and wires to ensure correct installation.
Cap and plug all lines and fittings to prevent any contaminants from entering the system.
Use drain pan to catch any oil that may drain from system. Dispose of oil IAW local policy
and ordinances. Ensure all spills are cleaned up.
4.
Remove four hose assemblies (Figure 2, Item 10) from propel control valve (Figure 2, Item 5).
5.
Disconnect electrical connector (Figure 2, Item 8).
6.
Remove two wires (Figure 2, Item 7) from backup alarm switch (Figure 2, Item 9).
7.
Remove four bolts (Figure 2, Item 2) and nuts (Figure 2, Item 3) from plate assembly (Figure 2, Item 6).
8.
Remove propel control valve (Figure 2, Item 5) and lever assembly (Figure 2, Item 4) as a unit from plate
assembly (Figure 2, Item 6).
1
2, 3
4
5
6
10
9
8
7
M0361SWR
Figure 2.
Propel Control Lever Removal.
END OF TASK