TM 5-3895-379-23-1
0168
REMOVAL
1.
Remove two shoulder screws (Figure 1, Item 1), washers (Figure 1, Item 2), and vandal guard
(Figure 1, Item 3) from instrument box assembly (Figure 1, Item 4).
2.
Remove three screws (Figure 1, Item 5) and washers (Figure 1, Item 6) from operator station
(Figure 1, Item 7).
3.
Lift and tilt back instrument box assembly (Figure 1, Item 4) to gain access to back of instrument box assembly.
3
2
1
7
6
5
4
M0901SWR
Figure 1. Fuel Level Gauge Removal.
4.
Pull light fixture (Figure 2, Item 6) and remove light fixture from fuel level gauge (Figure 2, Item 1).
5.
Remove retainer clip (Figure 2, Item 7) from light fixture (Figure 2, Item 6).
6.
Push and twist light bulb (Figure 2, Item 2) counterclockwise and remove light bulb from light fixture
(Figure 2, Item 6).
7.
If damaged, cut wire (Figure 2, Item 5) below contact (Figure 2, Item 8) and remove contact, cap
(Figure 2, Item 3), spring (Figure 2, Item 4), and light fixture (Figure 2, Item 6) from wire.
03/15/2011Rel(1.8)root(maintwp)wpno(M00106)