Figure 5. Thermostat Housing Installation.
THERMOSTAT HOUSING REPLACEMENT (CB534C)

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  751    752    753    754    755  756  757    758    759    760    761  
img
. .
TM 5-3895-379-23-1
0142
INSTALLATION - Continued
2
1
5
4
3
10
6
9
7
8
M1068SWR
Figure 6. Thermostat Housing Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Fill coolant system. (WP 0139)
2.
Lower operator platform assembly. (Volume 2, WP 0235)
3.
Start engine and allow engine to idle until coolant reaches normal operating temperature. Run engine five
minutes. Check for leaks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE
0142-7/8 blank