TM 5-3895-379-23-1
0142
INSTALLATION
1.
Install two pipe plugs (Figure 4, Item 7) in thermostat housing assembly (Figure 4, Item 6).
2.
Install thermostat (Figure 4, Item 9), new preformed packing (Figure 4, Item 8), and connector
(Figure 4, Item 4) in thermostat housing assembly (Figure 4, Item 6).
3.
Install bolts (Figure 4, Items 1 and 3) in thermostat housing assembly (Figure 4, Item 6). Tighten bolt to
177-301 lb-in. (20-34 Nm). Install bolt (Figure 4, Item 1) in thermostat housing assembly (Figure 4, Item 6).
Tighten bolt to 177-301 lb-in. (20-34 Nm).
4.
Install four screws (Figure 4, Item 2) in thermostat housing assembly (Figure 4, Item 6). Tighten screws to
177-301 lb-in. (20-34 Nm).
5.
Position new gasket (Figure 4, Item 5) on thermostat housing assembly (Figure 4, Item 6).
2
2
1
3
4
9
5
8
7
6
M1251SWR
Figure 4. Thermostat Housing Installation.