TM 5-3895-379-23-1
0142
INSTALLATION - Continued
6.
Position hose (Figure 5, Item 3) onto thermostat housing assembly (Figure 5, Item 1).
7.
Install two bolts (Figure 5, Item 5) and bolt (Figure 5, Item 6) in thermostat housing assembly
(Figure 5, Item 1). Tighten bolt to 177-301 lb-in. (20-34 Nm). Install two screws (Figure 5, Item 7) in thermostat
housing assembly (Figure 5, Item 6). Tighten screws to 33-47 lb-ft (45-64 Nm).
8.
Install two bolts (Figure 5, Item 4) in thermostat housing assembly (Figure 5, Item 1). Tighten bolts to
33-47 lb-ft (45-64 Nm).
1
7
2
6
5
4
3
M1070SWR
Figure 5. Thermostat Housing Installation.
9.
Install clamp (Figure 6, Item 9) on hose (Figure 6, Item 8) and thermostat housing assembly
(Figure 6, Item 10). Tighten clamp until secure.
10.
Install clip (Figure 6, Item 3) and screw (Figure 6, Item 6) in thermostat housing assembly (Figure 6, Item 10).
Tighten screw to 177-301 lb-in. (20-34 Nm).
11.
Install temperature sensor (Figure 6, Item 7) in thermostat housing assembly (Figure 6, Item 10).
12.
Connect temperature sensor connector (Figure 6, Item 5) to connector (Figure 6, Item 4).
13.
Install top radiator hose (Figure 6, Item 2) and clamp (Figure 6, Item 1) on thermostat housing assembly
(Figure 6, Item 10). Tighten clamp securely.
03/15/2011Rel(1.8)root(maintwp)wpno(M00080)