TM 5-3895-379-23-1
0032
CORRECTIVE ACTION - Continued
Table 1. Maximum Acceptable System Voltage Drops During Cranking.
CIRCUIT
24V SYSTEM
Battery (-) post to starter (-) terminal
1.4 Volts
Drop across battery disconnect switch
1.0 Volts
Battery (+) post to starter solenoid (+) terminal
1.0 Volts
Starter solenoid BAT terminal to MTR terminal
0.8 Volts
STARTER TERMINAL MOTOR
STARTER SOLENOID
SOLENOID TERMINAL
STARTER
VIEW LOOKING UP
BATTERY TERMINAL
FROM UNDER ROLLER
T0198SWR
Figure 4.
Battery Cable Connections at Starter.