MALFUNCTION
Starter Relay Faulty.
CORRECTIVE ACTION
1.
Have assistant turn and hold engine start switch to START (full right) position (TM 5-3895-379-10)
for not more than 30 seconds.
2.
Touch positive (+) probe of multimeter to (wire 306-GN) of starter relay.
3.
a.
If 24 to 28 VDC are not present at start relay output, go to next malfunction.
b.
If 24 to 28 VDC are present at (wire 306-GN), replace starter relay (WP 0153).
STARTER RELAY
WIRE 306-GN
WIRE 200-BK
WIRE
109-OR
OUTPUT
TERMINAL
WIRE
304-WH
INPUT TERMINAL
T0200SWR
Figure 7. Starter Relay Wiring.