Figure 1. Battery Cable Connections at Starter.
Figure 3. Battery Cable Connections at Starter.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  179    180    181    182    183  184  185    186    187    188    189  
img
. . . .
TM 5-3895-379-23-1
0032
MALFUNCTION
Batteries Faulty.
CORRECTIVE ACTION
WARNING
Remove all jewelry such as rings, dog tags and bracelets. If jewelry contacts
electrical connection, a direct short may occur resulting in injury or death to
personnel and damage to equipment.
Use caution while working under operator platform assembly. Falling platform
may cause injury or death.
Inspect batteries (WP 0190) and test batteries (WP 0190).
If batteries are damaged or bad, replace batteries (WP 0190).
BATTERIES
BATTERY CABLES
T0089SWR
Figure 2.
Batteries and Battery Cables.
0032-4
03/15/2011Rel(1.8)root(tswp)wpno(T00038)