TM 5-3895-383-24
9.
Remove two O-ring seals (13) from other side of flange
(11). Check the O-ring seal for wear or damage and
replace if necessary.
NOTE: For correct assembly, note the orientation of the
wear plate.
10.
Remove wear plate (14).
11.
Remove four bolts (15). Remove block (16) from
housing.
12.
Remove port plate (17).
NOTE: For correct assembly, note the orientation of the
port plate (17) and dowel (18) before removing the
port plate from the block.
13.
Remove nut (20) from solenoid (19). Remove the
solenoid (19).