TM 5-3895-383-24
Starter
For starter information refer to the supplement contained in this
Service Manual.
Alternator
For alternator information refer to the supplement contained in
this Service Manual.
Fuel Shutoff Solenoid
Energized To Shutoff (ETS)
(Latching Type)
NOTE:
Engines with latching type solenoids may be
manually shut off by pushing in on button "1".
The solenoid CANNOT be manually latched in the
run position for starting.
8C3662 (12 VDC)
When installing to governor housing, tighten to a torque of 30
± 5 Nm (22 ± 4 lb-ft)
Resistance a 25C (77F)
Pull-in coil .....................................................1.15± 1.1 ohms
Hold-in coil......................................................48 4.8 ohms
Hold-in force must hold in spring at 9.6 VDC after being heat
stabilized at 121C (250F) ambient and 28.8 VDC.
Plunger stroke (A) when de-energized .............. 17.0 mm (.67 in)
Position (B) when energized ............ 26.8 ± 1 mm (1.06 .04 in)
155-4652 (24 VDC)
When installing to governor housing, tighten to a
torque of.....................................................30 ± 5 Nm (22 ± 4 lb-ft)
Resistance at 25C (77F)
Pull-in coil ....................................................1.55 1.0 ohms
Hold-in coil...................................................10.3 ± 1.0 ohms
Hold-in force must hold in spring at 9.6 VDC after being heat
stabilized at 121C (250F) ambient and 28.8 VDC.
Plunger stroke (A) when de-energized ............................17.0 mm
(.67 in)
Position (B) when energized ......................................26.8 ± 1 mm
(1.06 ± .04 in)
Energized To Run (ETR)
(Non-Latching Type)
9X5302 (12 VDC)
When installing to governor housing, tighten to a
torque of....................................... 50 ± 10 N m (36.77 ± 7.35 lb-ft)
Resistance at 25C (77F)
Pull-in coil .....................................................0.28 ±.03 ohms
Hold-in coil......................................................12 ± 1.2 ohms
Hold-in force must hold in spring at 4.8 VDC after being heat
stabilized at 121C (250F) ambient and 144 VDC.
Plunger stroke (A) when de-energized .............17.0 mm (.66 in)
Position (B) when energized .............26.8 ± 1.0 mm (1.06 ± .04 in)
5-42