TM 5-3895-383-24
3EO268 (24 VDC)
When installing to governor housing, tighten to a
torque of.....................................................30 ± 5 N m (22 ± 4 lb-ft)
Resistance at 250C (77F)
Pull-in coil ....................................................1.15 ± 1.1 ohms
Hold-in coil......................................................48 ± 4.8 ohms
Hold-in force must hold in spring at 9.6 VDC after being heat
stabilized at 121C (250F) ambient and 28.8 VDC.
Plunger stroke (A) when de-energized .............. 17.0 mm (.66 in)
Position (B) when energized ............ 26.8 ± 1 mm (1.06 ± .04 in)
Wiring Connections For Fuel Shutoff Solenoid
Energized To Shut-Off (ETS)
(Latching Type)
End View Of Shutoff Solenoid
(1)
Ground terminal. Use 10 gauge wire to ground.
(2)
Stop terminal. Use 16 gauge wire to OFF terminal of
key switch.
(3)
Start terminal. Use 10 gauge wire to S (switch) terminal
of starter motor.
Energized To Run (ETR)
(Non-Latching Type)
End View of ETR Shutoff Solenoid
There is no polarity (+, - ) requirements for this 2 wire solenoid.
5-43