TM 5-3895-383-24
Indicators and Gauges - Test
SMCS Code: 7450-081
Illustration 273
Illustration 274
Look for gauges that are broken. Look for indicator lights that
area inoperative. Look for switches that are broken.
Start the engine.
Sound the horn.
Look for inoperative gauges.
Turn on all of the machine lights. Check for proper operation.
Stop the engine.
NOTE:
When the engine is stopped and the engine start
switch key is turned to the ON position, all four of
the indicator lights should illuminate. If the
indicator lights do not illuminate, repair the lights
or replace the lights.
Make all necessary repairs before operating the machine.
Leveling Blade Cylinder - Lubricate
SMCS Code: 6060-086-CD; 6151-086-CD
NOTE:
Clean the fittings before you lubricate the fittings.
Illustration 275
Lubricate the grease fitting that is located at the top of the
leveling blade cylinder.
Illustration 276
Lubricate the grease fitting that is located at the bottom of the
leveling blade cylinder.
Maintenance Section
Indicators and Gauges - Test
1-115