TM 5-3895-379-23
CRANKSHAFT PULLEY REPLACEMENT - CONTINUED
0167 00
CLEANING AND INSPECTION
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning components.
DO NOT direct compressed air against human skin. Failure to follow this warning may cause injury or
death. Make sure air stream is directed away from user and other personnel in the area. To prevent
injury, user must wear eye protection.
1.
Clean removed parts with detergent. Dry parts with compressed air.
2.
Inspect counter-balance weight and crankshaft pulley for cracks or other damage. Replace if damaged.
3.
Inspect wear of pulley grooves. Replace pulley if worn.
4.
Inspect to ensure plastic mandrel and seal lip maintains the correct shape, if supplied.
INSTALLATION
1.
Apply a coat of lubricating oil to exposed surface of crankshaft end (3).
2.
If supplied, remove plastic mandrel from seal, if required.
NOTE
Position counterbalance weight to align holes with crankshaft end.
Apply sealing compound to threads of bolts.
It may be necessary to keep crankshaft from rotating when installing bolts.
3.
Position crankshaft pulley (4) on crankshaft end (3).
4.
Install counterbalance weight (2) and three bolts (1). Tighten bolt to 85 lb-ft (115 Nm).
3
4
2
5
1
401-956
401-2066
5.
6.
END OF WORK PACKAGE