TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Roller Has No Electrical Power - 11. Check for power output at engine 1. If 24 to 28 Vdc are not present at
1.
start switch. Push propel control
RELAY terminal (wire 103-YL),
Continued.
lever forward to prevent engine
replace engine start switch (WP
start-up. Touch positive (+) probe
terminal (wire 103-YL) of engine 2. If 24 to 28 Vdc are not present at
START terminal (wire 307-OR),
start switch. Touch negative (-)
replace engine start switch (WP
ground. Turn and hold engine
start switch to start (full right) 3. If 24 to 28 Vdc are present at
position (TM 5-3895-379-10).
START and RELAY terminals,
Measure voltage output. Move
replace or repair wiring (wire 103-
positive (+) probe of multimeter
YL or 307-OR) and connectors to
to START terminal (wire 307-
OR) of engine start switch.
Measure voltage. Turn engine
start switch to OFF position (TM
5-3895-379-10).
SHOULDER
WASHER
SCREW
WIRE
START
307-OR
TERMINAL
VANDAL
BAT
GUARD
TERMINAL
OPERATOR
WIRE 105-BR
STATION
RELAY
WIRE
ENGINE
INSTRUMENT
WASHER
TERMINAL
103-YL
START
PANEL
SCREW
SWITCH
401-194
0006 00-52