TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1.
Roller Has No Electrical Power - 2.
Inspect batteries (WP 0103 00) 1. If
batteries are damaged or
bad,
and test batteries.
Continued.
2. If batteries are OK, go to Step 3.
STARTER
VIEW LOOKING UP
BATTERY TERMINAL
FROM UNDER ROLLER
401-190
3. Check battery cables and 1. If battery cable connectors are
connectors for looseness or
loose, tighten connectors (WP
damage such as corrosion,
fraying,
broken
terminals,
connectors are damaged, replace
cracked or missing insulation or
kinking.
2. If battery cables are not damaged
and connectors are not loose,
0006 00-47