TM 5-3895-379-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 2. Electrical Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Roller Has No Electrical Power - 7.
Check for power to
main relay 1. If 24 to 28
Vdc are not measured
1.
at input terminal (wire 109-OR),
Continued.
Remove seven screws and
replace or repair wire 109-OR and
washers and two screws and
washers and remove panel from
operator station. Touch positive 2. If 24 to 28 Vdc are measured at
input terminal (wire 109-OR), go
to Step 8.
terminal (wire 109-OR) and
negative (-) probe of multimeter
to good ground.
8. Check power to coil of main 1. If 24 to 28 Vdc are not measured
relay. Disconnect main relay
at terminal 1 (wire 308-YL) and
connector
from
harness
KEY START fuse is good, turn off
connector. Turn engine start
engine start switch (TM 5-3895-
switch to ON position (TM 5-
379-10) and go to Step 10.
3895-379-10). Touch positive (+)
probe of multimeter to terminal 1 2. If 24 to 28 Vdc are measured at
terminal 2, connect main relay
(wire 308-YL) and negative (-)
connector to harness connector.
probe of multimeter to good
Go to Step 9.
ground.
PANEL
SCREW
ASSEMBLY
WASHER
WASHER
WIRE
112-PU
WIRE 109-OR
SCREW
WIRE
308-YL
MAIN
RELAY
HARNESS
CONNECTOR
OPERATOR
STATION
401-193
0006 00-50