TM 5-3895-379-23-2
0270
INSTALLATION
1.
Install clamp half (Figure 3, Item 1), water spray pump (Figure 3, Item 8), clamp half (Figure 3, Item 1), plate
(Figure 3, Item 10), and two screws (Figure 3, Item 11) on bumper assembly (Figure 3, Item 9). Tighten screws
securely.
2.
Position two hose assemblies (Figure 3, Item 4) on elbows (Figure 3, Item 2) and tighten two clamps
(Figure 3, Item 3).
3.
Install two elbows (Figure 3, Item 2) and hose assemblies (Figure 3, Item 3) on water spray pump
(Figure 3, Item 8).
NOTE
Add electrical tiedown straps as required.
4.
Connect water spray pump connector (Figure 3, Item 5) to connector (Figure 3, Item 6).
5.
Turn valve handle (Figure 3, Item 7) to open position and check for leaks.
1
23
1
4
5
6
CLOSED
OPEN
11
7
10
8
2
3
4
9
M1138SWR
Figure 3. Water Spray Pump Installation.
03/15/2011Rel(1.8)root(maintwp)wpno(M00208)