Figure 1. Water Spray Strainer Removal.
Figure 2. Water Spray Strainer Assembly.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 2 Page Navigation
  297    298    299    300    301  302  303    304    305    306    307  
img
TM 5-3895-379-23-2
0271
CLEANING AND INSPECTION
1.
Clean strainer assembly bowl and screen with non-sudsing detergent and water. Remove difficult deposits
with a cleaning brush.
WARNING
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may cause injury or death. Make sure air stream is directed away from user and
other personnel in the area. To prevent injury, user must wear protective goggles or face
shield.
2.
Use cleaning cloth or compressed air to dry metal parts.
3.
Check bowl for cracking, corrosion or excessive wear.
4.
Check screen for clogging, corrosion, excessive wear and obvious signs of damage.
5.
Check all parts for stripped or damaged threads.
6.
Replace all damaged threads.
END OF TASK