• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
VIBRATORY COOLING/CONTROL VALVE REPLACEMENT
Figure 1. Vibratory Cooling/Control Valve Removal.

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 2 Page Navigation
  176    177    178    179    180  181  182    183    184    185    186  
img
TM 5-3895-379-23-2
0254
REMOVAL
WARNING
Oil is very slippery. Immediately wipe up any spills. Failure to follow this warning may cause
injury.
NOTE
Use drain pan to catch any hydraulic oil that may drain from system. Dispose of oil IAW
local policy and ordinances. Ensure all spills are cleaned up.
Mark and tag two electrical connectors for installation purposes.
1.
Disconnect two electrical connectors (Figure 1, Item 3) from vibratory cooling/control valve (Figure 1, Item 6).
2.
Remove electrical tiedown strap (Figure 1, Item 1) that fastens electrical harness to bracket (Figure 1, Item 2).
NOTE
Cap and plug all lines and fittings to prevent any contaminants from entering the system.
3.
Disconnect seven hose assemblies (Figure 1, Item 4) from vibratory cooling/control valve (Figure 1, Item 6).
4.
Remove six bolts (Figure 1, Item 5) securing vibratory cooling/control valve (Figure 1, Item 6) to vibratory pump
(Figure 1, Item 9).
WARNING
Use caution when handling heavy parts. Provide adequate support and use assistance during
procedure. Failure to follow this warning may cause injury.
NOTE
Weight of vibration cooling/control valve is 62 lb (28 kg).
5.
With assistance, remove vibratory cooling/control valve and spacer (Figure 1, Item 7).
6.
Remove four O-rings (Figure 1, Item 8) from spacer (Figure 1, Item 7) and vibratory cooling/control valve
(Figure 1, Item 6). Discard O-rings.
0254-2
03/15/2011Rel(1.8)root(maintwp)wpno(M00192)


Privacy Statement