TM 5-3895-379-23-1
0195
SOLDERLESS TERMINAL REPLACEMENT
CAUTION
Terminals come in different styles and sizes. To prevent equipment damage, be sure to use
only exact replacements. Do not attempt to modify terminal to fit.
1.
Remove old terminal (Figure 1, Item 1) and trim end of wire (Figure 1, Item 2) as required.
NOTE
If trimming causes wire to become too short, refer to WIRE SPLICING USING BUTT
CONNECTORS or WIRE SPLICING USING SOLDER METHOD in this work package.
2.
Remove insulation (Figure 1, Item 3) from wire (Figure 1, Item 2) and equal to dimension A.
NOTE
Be sure all strands of wire are inside terminal when installing terminal to wire.
3.
Install terminal (Figure 1, Item 1) over bare end of wire (Figure 1, Item 2).
4.
Crimp terminal (Figure 1, Item 1) firmly in place.
A
1
2
3
M0994SWR
Figure 1. Solderless Terminal Replacement.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00133)