Figure 3. Battery Disconnect Switch Installation
BATTERY CABLE REPLACEMENT

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  992    993    994    995    996  997  998    999    1000    1001    1002  
img
.
TM 5-3895-379-23-1
0191
INSTALLATION - Continued
4.
Install cable (Figure 4, Item 4) on negative (-) terminal (Figure 4, Item 2) of battery (Figure 4, Item 1) with nut
(Figure 4, Item 3).
3
4
1
2
M1199SWR
Figure 4. Battery Disconnect Switch Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
Lower operator platform assembly. (Volume 2, WP 0235)
END OF TASK
END OF WORK PACKAGE
0191-5/6 blank