BATTERY DISCONNECT SWITCH REPLACEMENT
Figure 2. Battery Disconnect Switch Removal

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  989    990    991    992    993  994  995    996    997    998    999  
img
.
TM 5-3895-379-23-1
0191
REMOVAL
CAUTION
Always disconnect the negative (-) battery cable before servicing the battery or positive
(+) battery cable. Failure to do so can result in damage to electrical system.
Do not allow battery cable ends to contact each other or roller. Failure to follow this
caution may cause damage to battery or electrical system.
NOTE
Tag and mark all wires prior to removal.
1.
Loosen nut (Figure 1, Item 3) and remove cable (Figure 1, Item 4) from negative (-) terminal (Figure 1, Item 2)
on battery (Figure 1, Item 1).
3
4
1
2
M0974SWR
Figure 1. Battery Disconnect Switch Removal.
0191-2