TM 5-3895-379-23-1
0191
INSTALLATION
NOTE
Use alignment pin on battery disconnect switch to ensure proper placement of switch and
plate.
1.
Install battery disconnect switch (Figure 3, Item 3) and new lockwasher (Figure 3, Item 1) on frame assembly
(Figure 3, Item 2). Install plate (Figure 3, Item 8), lockwasher (Figure 3, Item 1), and nut (Figure 3, Item 9) on
battery disconnect switch (Figure 3, Item 3). Install key (Figure 3, Item 10).
2.
Install two cables (Figure 3, Item 6) on battery disconnect switch (Figure 3, Item 3) with two new lockwashers
(Figure 3, Item 1) and nuts (Figure 3, Item 4).
3.
Position boot (Figure 3, Item 5) over cable (Figure 3, Item 6).
4
3
2
5
6
1
7
1
8
9
10
M1200SWR
Figure 3.
Battery Disconnect Switch Installation
03/15/2011Rel(1.8)root(maintwp)wpno(M00129)