TM 5-3895-379-23-1
0153
REMOVAL
NOTE
Tag and mark all wires prior to removal.
Remove electrical tiedown straps as required.
1.
Disconnect starter relay switch assembly connector (Figure 1, Item 5) from connector (Figure 1, Item 6).
2.
Remove two screws (Figure 1, Item 1), washers (Figure 1, Item 2), and starter relay switch assembly
(Figure 1, Item 4) from frame assembly (Figure 1, Item 3).
3
2
1
4
6
5
M0847SWR
Figure 1. Starter Relay Switch Removal.
3.
Position boot (Figure 2, Item 4) so that end of cable (Figure 2, Item 1) can be seen and remove two nuts
(Figure 2, Item 6), washers (Figure 2, Item 5), and two cables from starter relay switch assembly
(Figure 2, Item 2).
2
1
5
6
4
3
5
M0848SWR
Figure 2. Starter Relay Switch Removal.
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00091)