Figure 1. Alternator Circuit Breaker Removal.
STARTER REPLACEMENT

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  790    791    792    793    794  795  796    797    798    799    800  
img
.
TM 5-3895-379-23-1
0151
INSTALLATION
1.
Install circuit breaker (Figure 2, Item 4) on air cleaner support assembly (Figure 2, Item 3) with two new
lockwashers (Figure 2, Item 2) and screws (Figure 2, Item 1).
2.
Install two terminals (Figure 2, Item 6) and terminal (Figure 2, Item 5) on circuit breaker assembly
(Figure 2, Item 4) with two new lockwashers (Figure 2, Item 7) and screws (Figure 2, Item 8). Tighten screws
to 24-48 lb-in (3-5 Nm).
3.
Position cable boots (Figure 2, Item 9) to cover two terminals (Figure 2, Item 6) and terminal
(Figure 2, Item 5).
3
1
2
4
5
6
7
8
9
VIEW FROM BACK SIDE
OF ALTERNATOR CIRCUIT BREAKER
M0838SWR
Figure 2. Alternator Circuit Breaker Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close left-side door assembly. (TM 5-3895-379-10)
2.
Remove chocks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE
0151-3/4 blank
03/15/2011Rel(1.8)root(maintwp)wpno(M00089)