TM 5-3895-379-23-1
0151
INSTALLATION
1.
Install circuit breaker (Figure 2, Item 4) on air cleaner support assembly (Figure 2, Item 3) with two new
lockwashers (Figure 2, Item 2) and screws (Figure 2, Item 1).
2.
Install two terminals (Figure 2, Item 6) and terminal (Figure 2, Item 5) on circuit breaker assembly
(Figure 2, Item 4) with two new lockwashers (Figure 2, Item 7) and screws (Figure 2, Item 8). Tighten screws
to 24-48 lb-in (3-5 Nm).
3.
Position cable boots (Figure 2, Item 9) to cover two terminals (Figure 2, Item 6) and terminal
(Figure 2, Item 5).
3
1
2
4
5
6
7
8
9
VIEW FROM BACK SIDE
M0838SWR
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close left-side door assembly. (TM 5-3895-379-10)
2.
Remove chocks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE
03/15/2011Rel(1.8)root(maintwp)wpno(M00089)