TM 5-3895-379-23-1
0151
REMOVAL
NOTE
Tag and mark wires prior to removal.
1.
Position cable boots (Figure 1, Item 9) to expose two terminals (Figure 1, Item 6) and terminal
(Figure 1, Item 5).
2.
Remove two screws (Figure 1, Item 8), lockwashers (Figure 1, Item 7), and terminals (Figure 1, Item 6) and
terminal (Figure 1, Item 5) from circuit breaker assembly (Figure 1, Item 4). Discard lockwashers.
3.
Remove two screws (Figure 1, Item 1), lockwashers (Figure 1, Item 2), and circuit breaker assembly
(Figure 1, Item 4) from air cleaner support assembly (Figure 1, Item 3). Discard lockwashers.
3
1
2
4
5
6
7
8
9
VIEW FROM BACK SIDE
M0837SWR
END OF TASK
03/15/2011Rel(1.8)root(maintwp)wpno(M00089)