TM 5-3895-379-23-1
0144
REMOVAL
NOTE
Water pump is replaced the same way for CB534B and CB534C Rollers except where
noted. CB534B Roller is shown.
Inspect all hoses, lines, and fittings for cracks, bends, nicks, dents, stripped threads, and
cuts. Replace all damaged parts.
1.
Loosen clamp (Figure 1, Item 2) and remove hose (Figure 1, Item 3) from water pump (Figure 1, Item 1).
1
2
3
M0630SWR
Figure 1. Water Pump Removal.
2.
Remove two bolts (Figure 2, Item 5) and washers (Figure 2, Item 4) from front fan guard assembly
(Figure 2, Item 3).
3.
Remove two bolts (Figure 2, Item 2), washers (Figure 2, Item 1), and front fan guard assembly
(Figure 2, Item 3) from fan shroud (Figure 2, Item 6).
1
2
3
4
6
5
M0631SWR
Figure 2. Water Pump Removal.
4.
For CB534B Roller, remove two bolts (Figure 3, Item 2) from connector (Figure 3, Item 3).
5.
For CB534B Roller, remove bolts (Figure 3, Items 1 and 5) from water pump (Figure 3, Item 4).
03/15/2011Rel(1.8)root(maintwp)wpno(M00082)