TM 5-3895-379-23-1
0120
INSTALLATION - Continued
2.
Install adapter (Figure 4, Item 4) on adapter (Figure 4, Item 9).
3.
Install adapter (Figure 4, Item 9) on mounting bracket (Figure 4, Item 3) with two washers (Figure 4, Item 7),
screws (Figure 4, Item 8), and nuts (Figure 4, Item 6). Tighten screws to 108-180 lb-in. (12-20 Nm).
4.
Install tube (Figure 4, Item 5) on adapter (Figure 4, Item 4).
5.
Install service indicator (Figure 4, Item 1) on adapter (Figure 4, Item 9) by turning clockwise.
6.
Push button (Figure 4, Item 2) on service indicator (Figure 4, Item 1) to reset.
REMOVE
INSTALL
2
1
5
3
4
9
6
8
7
M0492SWR
Figure 4. Air Cleaner Service Indicator Installation.
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close left-side door assembly. (TM 5-3895-379-10)
2.
Remove chocks. (TM 5-3895-379-10)
END OF TASK
END OF WORK PACKAGE
03/15/2011Rel(1.8)root(maintwp)wpno(M00058)