Table 1. Preventive Maintenance Checks and Services (PMCS) (Annual) for CB534 Roller - Continued.
PMCS Mandatory Replacement Parts List

Technical Manual For Roller, Motorized, Vibrating Tandem Steel Drums - 1 Page Navigation
  348    349    350    351    352  353  354    355    356    357    358  
img
. . . . . . . .
TM 5-3895-379-23-1
0074
FIELD MAINTENANCE
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) (BIENNIAL)
INITIAL SETUP:
References (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive
WP 0101
(Volume 2, WP 0289, Table 1, Item 39)
WP 0139
Materials/Parts
Equipment Condition
Antifreeze: Permanent, Ethylene Glycol, Inhibited
Park roller. (TM 5-389-379-10)
Drums chocked. (TM 5-389-379-10)
(Volume 2, WP 0288, Table 1, Item 5, 6, 7)
Lubricating Oil, Gear, 80W-90 Grade
(Volume 2, WP 0288, Table 1, Item 37, 38,
39)
Personnel Required
Construction Equipment Repairer 91L (2)
References
WP 0088
Table 1.
Preventive Maintenance Checks and Services (PMCS) (Biennial) for CB534 Roller.
ITEM TO BE
EQUIPMENT
ITEM
CHECKED OR
NOT READY/
NO.
INTERVAL
SERVICED
PROCEDURE
AVAILABLE IF:
1
Biennial
Engine
Adjust valve lash (WP 0088) every 24 months or 1,000
operating hours, whichever comes first.
2
Biennial
Engine
Remove and clean breather tube (WP 0101) every 12
Crankcase
months or 2,000 operating hours, whichever comes first.
Breather Tube
3
Biennial
Radiator
Change coolant (WP 0139) every 24 months or 2,000  Class III leaks or
operating hours, whichever comes first. Inspect for leaks excessive corrosion
found.
or loose hoses. Check for excessive corrosion.
4
Biennial
Water Spray
Every 24 months or 2,000 operating hours (whichever  Damaged parts found.
System
comes first), thoroughly clean water spray system lines,
valves, drain cocks, spray bars, water tanks, screens,
and nozzles. Check for damaged parts. Replace any
damaged parts.
1.  Check and service water spray system
(TM 5-3895-379-10).
2.  Check and service water spray screen
(TM 5-3895-379-10).
3.  Check and service water spray nozzles
(TM 5-3895-379-10).
0074-1