PNEUMATIC ISOLATOR (TIRE AND WHEEL) REMOVAL FOR REPAIR OR CHANGE
Driven End - Continued

Technical Manual For Roller, Vibratory, Self-Propelled Page Navigation
  27    28    29    30    31  32  33    34    35    36    37  
img
. . . .
Driven End - Figure 24 and reference figure 21.
12. Follow steps 1 thru 3.
13. Figure 24. Back off on lock nut holding magnetic
pick-up (8) into the bearing housing.  Unthread
magnetic pick-up out of bearing housing and tuck
into roller frame. If machine is not equipped with an
amplitude indicator, proceed with step 15.
FIGURE 26
16. Follow step 5 and reference figure 23.
17. Follow steps 7 thru 11.
18. Figure 27. In reassembly of the magnetic pick-up to
the gear (DD), the pick-up must be adjusted to have
FIGURE 24
an air gap of 0.30, then secure with lock nut. Inflate
tires to 25-28 PSI SP848.  Check tire pressure
weekly thereafter.
FIGURE 25
FIGURE 27
14. Figure 25. If machine is equipped with an amplitude
indicator, remove top pin (X) and drop mechanism
into roller frame. Remove two wheel bolts (W) and
remove bracket (Z).
15. Figure 24. Remove four bolts (9) holding bearing
flange to wheel mount and remove flange. Remove
remaining wheel bolts (10).