SECTION 7
TRANSMISSION
FIGURE 7-58.
FIGURE 7-60.
FIGURE 7-59.
FIGURE 7-61.
7-196. REMOVAL.
a. Disconnect hoses and remove pump or motor from
unit.
e. With fingers or two screwdrivers remove bronze
b. Insert Tru-Arc #7 pliers in snap ring holes, compress
CAUTION: Use care not to damage bronze rotating ring or
shaft splines.
c. Remove the aluminum
seal
retainer
with
a
f.
d. Remove the steel stationary seal.
This seal will
7-197. INSTALLATION.
usually come out with the retainer
7-41.