TM 5-3895-346-14
HYDROSTATIC SYSTEM
PUMP REPAIR
Figure 38.
Figure 39.
Install the trunnions, checking for proper orientation with the housing and tighten the capscrews. The
swashplate should have no sideplay yet rotate freely. If necessary, alter the plastic shims to obtain the proper
adjustment (refer to Fig. 39).
Figure 40.
Figure 41.
Install and tighten the trunnion capscrews (refer to Fig. 40).
Install the servo springs, if these parts were removed, using new screws (refer to Fig. 41).
Figure 42.
Figure 43.
The servo housings should be installed next (refer to Fig. 42).
Slide the housing over the servo piston and thread it into the pump housing (refer to Fig. 43).
545